Strike Connector Series
How-to instruction video for the DEUTSCH STRIKE Series.
Contact Insertion
- Ensure TPA locking is open.
- Hold connector with rear grommet/wire router facing you.
- Push contact straight into the grommet until a positive stop is felt. A slight tug will confirm that it is properly locked in place.
- Push to close the TPA. TPA will not close unless all contacts are fully seated in connector.
Contact Removal
- Remove the TPA with the appropriate removal tools.
- Unlock the contacts and pull on the wire.